Industrial Grating & Access System Solutions

EngineeringJul 2026By Wiberg Engineering Team

Stair Landings & Connections: What to Specify

Stair landings and connection components are the structural links that turn individual treads and handrails into a complete, code-compliant stair system. This guide covers landing dimensions per major standards, connection types, and the information to send for an accurate quotation.

Industrial steel stair landing with grating infill

Landing dimensions by standard

StandardMinimum depthWidthIntermediate landing
OSHA 1910.25762 mm (30 in)≥ stair widthNot mandated; practical limit ~3.6 m rise
EN ISO 14122-3800 mm≥ stair widthEvery 18 risers or 3 m rise
AS 1657750 mm≥ stair widthRecommended at every 18 risers
IBC 1011.6≥ stair width, ≤ 1220 mm (48 in)≥ stair widthRequired at > 3.66 m (12 ft) rise

Landing construction

A standard industrial stair landing consists of:

  • Frame: angle steel L75×75×8 or similar, welded to rectangular shape. S275JR / ASTM A36 material, hot-dip galvanized
  • Infill: serrated welded bar grating panel, sized to the frame opening
  • Edge banding: flat bar welded around the grating perimeter for finished edges
  • Toe plate: 100 mm high toe plate around open edges where required by code
  • Connection points: pre-drilled or welded brackets for stair stringer attachment and handrail post mounting

Connection components

The connections that join the system together are often overlooked in early specifications but are critical to site installation:

  • Tread-to-stringer brackets: angle steel 50 × 50 × 6 mm, bolted to tread end plates and stringer web. M12 bolts, ISO 898-1 Grade 8.8
  • Stringer-to-landing plates: 10–16 mm gusset plate welded to stringer end, bolted to landing frame. M16–M20 bolts
  • Handrail post base plates: 150 × 150 × 10 mm with four M12 bolt holes. Welded to post bottom, bolted to landing frame or tread end plate
  • Intermediate handrail brackets: where handrails exceed 2 m between posts, intermediate brackets connect the handrail to the stair stringer

What to include in your RFQ

Send the following for a complete stair package quotation:

  1. Total vertical rise and stair configuration (straight, switchback, spiral)
  2. Stair width and tread type preference (T2 welded, T4 bolt-on)
  3. Landing positions — heights above datum and dimensions
  4. Handrail type: single or dual rail, material and finish
  5. Governing project standard (OSHA / EN / AS / IBC)